Thermal Ground Testing of Loop Heat Pipes for PACE OCI

Thumbnail
Voir/Ouvrir
ICES-2022-412.pdf (2.278Mo)
Date
7/10/2022
Auteur
Semenov, Sergey
Patel, Deepak
Hoang, Triem
Stull, Christopher
Metadata
Afficher la notice complète
Résumé
A pair of propylene Loop Heat Pipes (LHP) designed for the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) Ocean Color Instrument (OCI) was tested in two configurations: flat (minimize the influence of gravity) and flight (bent/final configuration). The testing was conducted in the thermal vacuum chamber at NASA Goddard Space Flight Center facility. The test results are presented along with the lessons learned.
Citable Link
https://hdl.handle.net/2346/89863
Collections
  • International Conference on Environmental Systems

DSpace software copyright © 2002-2016  DuraSpace
Contactez-nous
TDL
Theme by 
Atmire NV
 

 

Parcourir

Tout DSpaceCommunautés & CollectionsPar date de publicationAuteursTitresSujetsDepartmentCette collectionPar date de publicationAuteursTitresSujetsDepartment

Mon compte

Ouvrir une sessionS'inscrire

Statistiques

Statistiques d'usage de visualisation

DSpace software copyright © 2002-2016  DuraSpace
Contactez-nous
TDL
Theme by 
Atmire NV