Investigation of the Anomalous Low Voltage Condition of the Oxygen Generation Assembly

Date

7/10/2022

Journal Title

Journal ISSN

Volume Title

Publisher

51st International Conference on Environmental Systems

Abstract

Hydrogen orbital replacement unit serial number 00002 of the oxygen generation assembly was exhibiting an increasingly anomalous low voltage condition in cell #1 of electrolysis cell stack serial number 00005. The hydrogen orbital replacement unit was removed on November 16, 2016, and the on-board spare hydrogen orbital replacement unit serial number 00003 installed to continue oxygen generation system operation. The removed orbital replacement unit was returned from the International Space Station to Collins Aerospace for test, teardown, and evaluation, and failure analysis.

Description

Phillip Baker, Collins Aerospace, US
Robert Roy, Collins Aerospace, US
Alesha Ridley, NASA, US
Steve Van Keuren, S&K Global Solutions, Inc., US
ICES404: International Space Station ECLS: Systems
The 51st International Conference on Environmental Systems was held in Saint Paul, Minnesota, US, on 10 July 2022 through 14 July 2022.

Keywords

Hydrogen Dome Assembly Orbital Replacement Unit, OGA, Oxygen Generation Assembly, Oxygen Generation System