Analysis Approach to Predict Condensation on International Space Station (ISS) Docking Systems

dc.contributor.advisor
dc.creatorPagan, Carlos
dc.creatorThacker, Karen
dc.date.accessioned2018-07-06 16:28
dc.date.available2018-07-06 16:28
dc.date.issued2018-07-08
dc.descriptionCarlos Pagan, Passive Thermal Control
dc.descriptionKaren Thacker, Materials Science
dc.descriptionICES207: Thermal and Environmental Control Engineering Analysis and Software
dc.descriptionThe 48th International Conference on Environmental Systems was held in Albuquerque, New Mexico, USA on 08 July 2018 through 12 July 2018.
dc.description.abstractWhen thermal analysis showed that interior temperatures of the NASA Docking System Block 1 (NDSB1) that will be used by future visiting vehicles of the International Space Station (ISS) could be lower than the air dewpoint temperature during the initial post-docking phase, a method was developed to evaluate the worst-case impact and design verification approach. This analysis was performed in three phases. In phase 1, the Boeing Passive Thermal Control Systems (PTCS) Team performed a thermal analysis using an integrated ISS model to determine the interior component transient temperatures. Using this data, Phase 2 was executed by the Boeing Environmental Control and Life Support (ECLS) team to determine the amount of water that could condense, its distribution over the various surfaces, and the amount of time required for it to evaporate. Rather than performing a complicated computational fluid dynamic (CFD) analysis that would have impacted design schedules, the problem was simplified by making conservative assumptions, and a spreadsheet was used to perform the calculations. The results, which are intentionally conservative for both the duration and amount of exposure to water, were then evaluated in Phase 3 by the Boeing Materials and Processes (M&P) team to determine if corrosion or other degradation would result, and if so, advise how to address material compatibility issues. The purpose of this paper is to discuss the analysis method for determining the locations, quantity, and durations of condensation exposure on the internal surfaces of NDSB1. A detailed discussion of Phase 3 is beyond the scope of this paper.en_US
dc.identifier.otherICES_2018_43
dc.identifier.urihttp://hdl.handle.net/2346/74056
dc.language.isoengen_US
dc.publisher48th International Conference on Environmental Systemsen_US
dc.subjectCondensation
dc.subjectdewpoint
dc.subjectThermal Control Systems
dc.titleAnalysis Approach to Predict Condensation on International Space Station (ISS) Docking Systemsen_US
dc.typePresentationen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ICES_2018_43.pdf
Size:
1012.98 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.57 KB
Format:
Item-specific license agreed upon to submission
Description: