dc.description.abstractSharp GP2Y1010 dust sensors are increasingly being used within distributed sensing networks and for personal monitoring of exposure to particulate matter (PM) pollution. These dust sensors offer an easy-to-use solution at an excellent price point; however, the sensors are known to offer limited dynamic range and poor limits of detection (L.O.D.), often >15 µg m−3. The latter figure of merit precludes the use of this inexpensive line of dust sensors for monitoring PM2.5 levels in environments within which particulate pollution levels are low. This manuscript presents a description of the fabrication and circuit used in the Sharp GP2Y1010 dust sensor and reports several effective strategies to minimize noise and maximize limits of detection for PM. It was found that measurement noise is primarily introduced within the photodiode detection circuitry, and that electromagnetic interference can influence dust sensor signals dramatically. Through optimization of the external capacitor and resistor used in the LED drive circuit—and the inter-pulse delay, electromagnetic shielding, and data acquisition strategy—noise was reduced approximately tenfold, leading to a projected noise equivalent limit of detection of 3.1 µg m−3. Strategies developed within this manuscript will allow improved limits of detection for these inexpensive sensors, and further enable research toward unraveling the spatial and temporal distribution of PM within buildings and urban centers—as well as an improved understanding of effect of PM on human health.
dc.identifier.citationThompson, J.E.. 2021. Improved measurement performance for the sharp gp2y1010 dust sensor: Reduction of noise. Atmosphere, 12(6). https://doi.org/10.3390/atmos12060775
dc.identifier.urihttps://doi.org/10.3390/atmos12060775
dc.identifier.urihttps://hdl.handle.net/2346/93455
dc.language.isoeng
dc.subjectDust sensor
dc.subjectInternet of things
dc.subjectIoT (internet of things)
dc.subjectParticulate matter
dc.subjectPM2.5
dc.titleImproved measurement performance for the sharp gp2y1010 dust sensor: Reduction of noise
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Main article with TTU Libraries cover page.pdf
Size:
2.64 MB
Format:
Adobe Portable Document Format

Collections