2014-10-202014-10-202014-07-13978-0-692-38220-2ICES-2014-309http://hdl.handle.net/2346/59673Tucson, ArizonaThe Orion Multi Purpose Crew Vehicle (MPCV) integrates the cabin and pressure suits with the core life support systems to provide life support during contingency depressurized cabin operations. To provide the multiple suit pressures between nominal pressurized cabin suited operations, suit leak checks, depressurized cabin suited operations, and elevated suit pressure for denitrification, a variable pressure regulator is needed. This paper documents the development and integrated testing of the Suit Loop Regulator (SLR) for Orion.engOrion Suit Loop Variable Pressure Regulator DevelopmentPresentation