Influence of impeller gap drainage width on the performance of low specific speed centrifugal pump

dc.creatorWei, Yangyang
dc.creatorYang, Yang (TTU)
dc.creatorZhou, Ling
dc.creatorJiang, Lei
dc.creatorShi, Weidong
dc.creatorHuang, Gaoyang
dc.date.accessioned2023-05-11T18:50:03Z
dc.date.available2023-05-11T18:50:03Z
dc.date.issued2021
dc.description© 2021 by the authors. Licensee MDPI, Basel, Switzerland. cc-by
dc.description.abstractThe centrifugal pump is one of the most important pieces of energy‐consuming equipment in various hydraulic engineering applications. This paper takes a low specific speed centrifugal pump as the research object. Based on the research method combining numerical calculation and experimental verification, the influence of the gap drainage structure on the performance of the low specific speed centrifugal pump and its internal flow field distribution were investigated. The flow field inside the low specific speed centrifugal pump impeller under different gap widths was stud-ied. The comparison between the numerical calculation results and the experimental results con-firms that the numerical calculations in this paper have high accuracy. It was found that the gap drainage will reduce the head of the low specific speed centrifugal pump, but increase its hydraulic efficiency. Using a smaller gap width could greatly improve the performance of the low specific speed centrifugal pump on the basis of a slight reduction in the head. The high‐pressure leakage flow at the gap flows from the blade pressure surface to the suction surface can effectively suppress the low‐pressure area at the impeller inlet. The flow rate of the high‐pressure leakage flow increases with the gap width. Excessive gap width may cause a low‐pressure zone at the inlet of the previous flow passage. These results could serve as a reference for the subsequent gap design to further improve the operating stability of the low specific speed centrifugal pump.
dc.identifier.citationWei, Y., Yang, Y., Zhou, L., Jiang, L., Shi, W., & Huang, G.. 2021. Influence of impeller gap drainage width on the performance of low specific speed centrifugal pump. Journal of Marine Science and Engineering, 9(2). https://doi.org/10.3390/jmse9020106
dc.identifier.urihttps://doi.org/10.3390/jmse9020106
dc.identifier.urihttps://hdl.handle.net/2346/93501
dc.language.isoeng
dc.subjectCentrifugal pump
dc.subjectGap drainage
dc.subjectLow specific speed
dc.subjectNumerical simulation
dc.subjectPerformance
dc.titleInfluence of impeller gap drainage width on the performance of low specific speed centrifugal pump