Pilot Investigation of a Novel Technique for Measuring Dynamic Body-Garment Contact

dc.creatorCompton, Crystal
dc.creatorDunne, Lucy
dc.date.accessioned2016-07-28T18:20:55Z
dc.date.available2016-07-28T18:20:55Z
dc.date.issued2016-07-10
dc.descriptionUnited States
dc.descriptionUniversity of Minnesota
dc.description400
dc.descriptionICES400: Extravehicular Activity: Space Suits
dc.descriptionVienna, Austria
dc.descriptionCrystal M. Compton, University of Minnesota-Twin Cities, USA
dc.descriptionLucy E. Dunne, University of Minnesota-Twin Cities, USA
dc.descriptionThe 46th International Conference on Environmental Systems was held in Vienna, Austria, USA on 10 July 2016 through 14 July 2016.
dc.description.abstractLiquid cooled garments are a fundamental aspect of regulating astronaut’s core body temperature during launch and entry and EVAs. They manage the thermal energy created by the body, to ultimately regulate the body’s core temperature and maintain a comfortable and safe working environment for the astronaut. Liquid cooled garments astronauts wear rely on conduction to transfer body heat. Heat from the body is conducted to a garment that contains cold flowing water. It is crucially important to have contact between the garment and body at all times and in all locations in order for the garment to work most efficiently using conduction. To effectively re-design a liquid cooling garment to promote good contact, it is important to first be able to diagnose where the problem areas exist. Therefore, a method to measure where the garment touches the body or not during movement could provide answers to not only improving the thermal regulation, but also the fit, comfort, and mobility of liquid cooled garments for future space exploration and human spaceflight. Existing methods of measuring the relationship between the body and garment rely on static imaging and are not able to measure contact while the body (and garment) is in motion. Here we present a novel method based on a ‘switch’-like principle, in which contact with the grounded body completes a circuit to close a switch attached to the digital input of a microcontroller. Working principle and early results of this method are discussed.
dc.format.mimetypeapplication/pdf
dc.identifier.otherICES_2016_149
dc.identifier.urihttp://hdl.handle.net/2346/67546
dc.language.isoeng
dc.publisher46th International Conference on Environmental Systems
dc.subjectLiquid cooling garment
dc.subjectLiquid cooling and ventilation garment
dc.subjectExtravehicular Mobility Unit
dc.subjectExtravehicular activity
dc.subjectThermal regulation
dc.subjectCore body temperature
dc.subjectContact
dc.subjectFit
dc.subjectComfort
dc.subjectMobility
dc.titlePilot Investigation of a Novel Technique for Measuring Dynamic Body-Garment Contact